Analytical-industries AII-2000 Palm O2 Oxygen Analyzer User Manual

Browse online or download User Manual for Equipment Analytical-industries AII-2000 Palm O2 Oxygen Analyzer. Analytical Industries AII-2000 Palm O2 Oxygen Analyzer User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Copyright © 6/11 All Rights Reserved
Analytical Industries Inc. dba Advanced Instruments Inc.,
2855 Metropolitan, Pomona, CA 91767 USA.
Tel: 909-392-6900, Fax: 909-392-3665
Email: [email protected], Web: www.aii1.com
This manual may not be reproduced in whole or in part without
the prior written consent of Analytical Industries Inc.
Page view 0
1 2 3 4 5 6 ... 13 14

Summary of Contents

Page 1

Copyright © 6/11 All Rights Reserved Analytical Industries Inc. dba Advanced Instruments Inc., 2855 Metropolitan, Pomona, CA 91767 USA. Tel: 909-392

Page 2 - 1 Introduction

16 17 5.4.1 Flowing Gas Streams (Breathing Circuits, Concentrators) 1. Place the sensing area of the sensor into the gas stream to be analyzed upst

Page 3

18 Procedure: 1. Open the enclosure: Remove the four (4) Phillips screws from the rear of the enclosure, FIG 1. 2. Separate the enclosure and an pla

Page 4

6.5 Oxygen Sensor Replacement - Optional Remote Sensor The design of the electronics is intended for only the Analytical Industries Inc. AII-11-75-PO2

Page 5 - 3 Safety Warnings

8 Specifications 22 8.1 Spare Parts & Optional Accessories 23 Accuracy: < 2% of FS range under constant conditions Anal

Page 6 - 4 Start-Up

24 9 Warranty Coverage Under normal operating conditions, the analyzer and sensors are warranted to be free of defects in materials and workmanship

Page 7

Table of Contents 1 Introduction 1 1.1 Indications for Use 1.2 Intended Use 1.3 Device Description 1.4 Declaration of

Page 8 - 5 Operation

The device is intended to be re-usable. Should the device or accessories come in contact with patient bodily fluids, either dispose of the device or c

Page 9

1.4 Declaration of Conformity We hereby declare the above product meets the provisions of the directives and standards specified. All supporting doc

Page 10 - 6 Maintenance

3 Safety Warnings ALWAYS follow the statements below as they are essential to reduc-ing the risk of use error due to ergonomic features of the device

Page 11

4 Start-Up 4.1 Contents of Shipping Container: The contents include:  AII-2000 Palm O2 Oxygen Analyzer  FITN-1112-1 Flow Diverter  P-1088 Instr

Page 12 - 7 Troubleshooting

Procedure Calibrate: (a) with a known source of dry 100% or 21% oxygen before using each day or after 8 hours of continuous use; (b) when the temperat

Page 13 - 8 Specifications

12 5 Operation 5.1 Principle of Operation The AII-2000 Palm O2 Oxygen Analyzer utilizes an electrochemical galvanic fuel cell type oxygen sensor of

Page 14 - 9 Warranty

14 The temperature dependent current signal output is compensated by using a resistor-thermistor network. With a proper resistor-thermistor network, t